Dataset: Dissolved trace metal (Mn, Fe, Co, Ni, Cu, Zn, Cd, Pb) concentrations from depth profile samples collected on the 2018 EXPORTS cruise (RR1813) to the subarctic North Pacific near Ocean Station PAPA (Station P) on R/V Roger Revelle

ValidatedFinal no updates expectedDOI: 10.26008/1912/bco-dmo.897253.1Version 1 (2023-07-06)Dataset Type:Cruise Results

Principal Investigator, Contact: Kristen Nicolle Buck (University of South Florida)

Co-Principal Investigator: Mark A. Brzezinski (University of California-Santa Barbara)

Co-Principal Investigator: Bethany D. Jenkins (University of Rhode Island)

Student: Shannon M. Burns (University of South Florida)

BCO-DMO Data Manager: Shannon Rauch (Woods Hole Oceanographic Institution)


Program: EXport Processes in the Ocean from Remote Sensing (EXPORTS)

Project: Collaborative Research: Diatoms, Food Webs and Carbon Export - Leveraging NASA EXPORTS to Test the Role of Diatom Physiology in the Biological Carbon Pump (Diatoms and carbon export)


Abstract

This dataset includes concentrations of dissolved (<0.2 micrometers (µm)) manganese (Mn), iron (Fe), cobalt (Co), nickel (Ni), copper (Cu), zinc (Zn), cadmium (Cd), and lead (Pb) in depth profile samples collected on 8 September 2018 during the EXports Processes in the Oceans from RemoTe Sensing (EXPORTS) cruise aboard R/V Roger Revelle cruise RR1813 at Ocean Station PAPA (Station P).

Samples for dissolved trace metal concentrations were collected using a trace metal clean (TMC) rosette (Measures et al. 2008) on the R/V Roger Revelle on 8 September 2018 (R2R event #RR1813-SE-20180908.1732.001). A total of 10 depths were sampled for dissolved (<0.2 micrometers (μm), Pall Acropak) trace metals, between 95 meters (m) to 825 m. All depths were sampled in triplicate for intercalibration; only the results from the Buck lab are reported here. Samples were collected in acid-cleaned 125-milliliter (mL) low-density polyethylene (LDPE, Nalgene) bottles, and acidified to 0.024 M hydrochloric acid (HCl, Fisher Optima). Dissolved trace metal (Fe, Cu, Mn, Co, Ni, Cu, Zn, Cd, Pb) concentrations were determined by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) at the University of South Florida (Burns et al. 2023).

Sample analyses for dissolved trace metals were performed by Shannon Burns (USF).


Related Datasets

No Related Datasets

Related Publications

Methods

Burns, S. M., Bundy, R. M., Abbott, W., Abdala, Z., Sterling, A. R., Chappell, P. D., Jenkins, B. D., & Buck, K. N. (2023). Interactions of bioactive trace metals in shipboard Southern Ocean incubation experiments. Limnology and Oceanography, 68(3), 525–543. Portico. https://doi.org/10.1002/lno.12290